Browse all practice questions for the Mosby Digital Image Acquisition Practice Test. Search by topic, open any question and review its full explanation, then test yourself in the practice quiz.

Mosby Digital Image Acquisition Practice Test course image
All questions

These questions are part of the practice quiz. Start practicing

  • Filtration has little effect on receptor exposure because x-rays removed from beam are not image-producing rays.
  • How do scatter, beam quality, and patient size interact to affect image contrast?
  • A radiographic image with few gray tones, primarily black and white, has which type of contrast?
  • Quality assurance and maintenance of CR cassettes include erasing plates at least:
  • Which statement correctly describes magnification in radiography?
  • Digital image receptors are more sensitive to which factor?
  • The process of assigning a value to each pixel to represent a gray tone is called:
  • Elongation and foreshortening are examples of:
  • If SID is doubled, what may be said about receptor exposure?
  • What is the impact of increasing the amount of processing on image quality?
  • A primary advantage to digital fluoroscopy is:
  • Using high kVp results in which type of contrast and grayscale?
  • The 15% rule states that:
  • What is a ghost image, and in which imaging mode is it most commonly a concern?
  • In digital radiography, what is the practical implication of wide detector latitude for exposure management?
  • Which parameter primarily influences beam energy and radiographic contrast?
  • The function of contrast is to:
  • How do direct conversion DR detectors differ from indirect conversion DR detectors?
  • Exposure indicators provide a numeric measure of detector exposure; consistent EI helps maintain uniform brightness.
  • Spatial resolution is defined as which of the following?
  • What is the effect of filtration on receptor exposure?
  • Name two common QA tests for DR systems.
  • What is the Moiré effect, and how can it be prevented in grid-based radiography?
  • Grid frequency is defined as:
  • Beam restriction reduces the number of Compton interactions, affecting contrast how?
  • Increasing beam filtration results in a beam described as harder. Which energy-related description is correct?
  • Why is mAs still a clinically important parameter in digital radiography?
  • When selecting a grid for digital radiography, which factor should be considered?
  • How does focal spot size influence geometric unsharpness and spatial resolution?
  • Which statement about the air gap technique is true?
  • Differential absorption of the x-ray beam is a function of which interaction?
  • What is the effect of increasing kVp on subject contrast?
  • If histogram indicates underexposure, which adjustments are typically considered?
  • How do grids influence image quality and patient dose in modern digital radiography?
  • What is the role of collimation in dose management and image quality?
  • In digital radiography inappropriate collimation can cause which of the following?
  • Which of the following affects receptor exposure?
  • GCF is defined as the amount of increase in kVp necessary when converting from nongrid to grid techniques.
  • Define detective quantum efficiency (DQE) and its impact on dose efficiency.
  • Beam-part-receptor alignment latitude describes which concept?
  • The range of source-to-image distances (SIDs) that may be used with a focused grid is called what?
  • Energy of the x-ray photons produced is primarily determined by:
  • mAs directly controls:
  • Which dose metric is commonly included in DR dose tracking?
  • Excessive processing of the digital image may:
  • Which statement describes the effect of using a smaller focal spot on spatial resolution?
  • Which metric combines dose and irradiated area to quantify the radiation exposure delivered to the patient?
  • What does the Modulation Transfer Function (MTF) describe in radiographic systems?
  • How do kVp and mAs collectively influence detector exposure, image contrast, and patient dose?
  • The portion of radiographic contrast caused by variations in anatomy or pathology is called?
  • Which statement describes the effect of beam restriction on radiographic contrast?
  • Why is post-processing used in digital radiography and what safeguards guide its use?
  • The expression of image quality provided by a detector is called:
  • If kVp is increased by 15% with the mAs unchanged, receptor exposure will approximately:
  • What is the primary mechanism by which grids improve image contrast?
  • In CR imaging, what term describes the plate that stores the latent image?
  • The actual patient dose as measured by a meter embedded in the collimator is:
  • Which grid design provides the best scatter cleanup?
  • Quality assurance and maintenance of CR cassettes include cleaning and inspecting the plates at least:
  • Which metric is used to evaluate the spatial resolution performance of a digital radiography system?
  • Why must DICOM header information be accurate and complete?
  • What is the impact of prosthetic materials on digital image acquisition, and how is it managed?
  • Which term describes the highest spatial frequency that can be recorded by a digital detector?
  • What is the role of QA in DR system maintenance and what are typical frequencies?
  • The smallest resolvable area in a digital imaging device is which?
  • As beam filtration increases, image contrast typically changes how?
  • Which of the following best describes the goal of uniform processing codes in digital imaging quality assurance?
  • Which term describes the range of receptor exposures that provides a quality image?
  • Which graphical representation displays the distribution of pixel values in an image?
  • The anode heel effect results in greater intensity toward which side of the beam?
  • Which material is used in direct conversion DR detectors?
  • Which principle states that the product of current and exposure time yields the same receptor exposure if the mAs is the same?
  • Why might exposure be increased when using a grid in digital radiography?
  • Distortion that occurs when the x-ray beam is angled against the long axis of a part is:
  • If SID is reduced by one half, what must be done to mAs to maintain a constant receptor exposure?
  • When using beam restriction, what adjustment is typically required for technical factors?
  • What is the consequence of poor exposure reproducibility on dose tracking and QA comparisons?
  • The smallest area represented in a digital image is the:
  • Magnification is caused by:
  • Distinguish between aliasing and Moiré; why are they concerns in digital imaging?
  • Beam-part-receptor alignment latitude describes the latitude of collimation that still allows what?
  • How does grid frequency influence the risk of Moiré patterns in digital radiography?
  • Which governs the relationship between SID and receptor exposure?
  • Undesirable fluctuations in image brightness are called?
  • How does histogram-based exposure evaluation aid technique adjustments after a chest radiograph?
  • Technique charts are most beneficial when manual techniques are used. Which option reflects this idea?
  • Which term is synonymous with the range of receptor exposures that yields diagnostic image quality?
  • What is automatic exposure control (AEC), and what is its main benefit?
  • To reduce patient dose, digital imaging technique should be adjusted by increasing kVp. Which option best represents this guidance?
  • Which of the following factors does NOT contribute to degraded spatial resolution?
  • Distortion may be described as:
  • Which term describes image distortion that mimics misrepresentation of an anatomic structure on the radiograph?
  • To maintain receptor exposure when using a grid, you should increase which parameter?
  • Quality assurance of digital imaging requires uniformity of processing codes to ensure what outcome?
  • In digital fluoroscopy, what equipment should be used to view the image?
  • Higher fill factor directly improves detection efficiency and signal-to-noise ratio.
  • Dose Area Product is best described as:
  • Which device is used to physically restrict the size and shape of the x-ray beam?
  • What is detector saturation, and why is it undesirable?
  • In general, anything interfering with accurate image formation is known as which term?
  • In digital images, what term describes the smallest unit of an image file that stores brightness information?
  • Low signal-to-noise ratio results in what effect on the image?
  • What is edge enhancement and when can it cause diagnostic errors?
  • How does patient motion affect image quality, and what strategies reduce motion artifacts?
  • The smallest resolvable detector unit is called which?
  • Improper use of grids may result in an image artifact known as:
  • How is dose tracking integrated into digital radiography systems?
  • What does flat-field calibration accomplish in detector uniformity?
  • The grid type designed with lead strips and interspacers angled to match beam divergence is called which grid type?
  • The variation of x-ray intensity along the longitudinal axis describes which phenomenon?
  • Digital imaging is driven by which factor?
  • Receptor exposure was formerly called:
  • Define bit depth and its effect on grayscale resolution.
  • If you change from a nongrid technique with 10 mAs at 75 kVp to using a 12:1 grid at 75 kVp, what mAs is needed to produce the same image?
  • What is the importance of monitor calibration in radiology imaging?
  • Nyquist frequency in detector sampling: which statement is correct?
  • Grid selectivity is defined as the ratio of primary radiation transmitted through the grid to secondary radiation transmitted through the grid.
  • Grid cutoff is most clearly described as which of the following?
  • Which of the following are primary factors that limit spatial resolution in a digital radiography system?
  • When AEC is used, increasing the kVp has which effect?
  • How does the appearance of digital images on technologists' monitors compare with radiologists' monitors?
  • The available grayscale of an imaging system is determined by which factor?
  • Visible differences in adjacent structures on a radiographic image describe:
  • Using a large focal spot will primarily affect image sharpness by:
  • In digital radiography, what does bit depth influence?
  • The active portion(s) of a CR IP is (are):
  • How does using a grid affect receptor exposure if mAs is not increased to compensate?
  • What is gray-scale mapping, and how can inappropriate mapping mislead diagnosis?
  • How are exposure indicators (EI) used to manage dose and image quality?
  • Which of the following is a correct pairing of artifact/phenomenon and its associated cause?
  • What is the primary purpose of grids?
  • Which artifact is least likely to be seen on a PSP plate?
  • Nyquist frequency and detector sampling: what is it and why is it relevant?
  • What are common PSP plate artifacts, and how can we mitigate them?
  • Mathematical codes used to generate the digital image are called:
  • If the pixel density increases, what happens to the detector's ability to resolve small details?
  • Which statement about focal-spot size is true according to the material?
  • Low-kVp technique is most associated with which type of contrast scale?
  • The radiographic image is formed by which of the following?
  • An artificial increase in display contrast at an edge of the image is called which?
  • Grid ratio is defined as:
  • What is the Last Image Hold feature and its clinical use?
  • How can exposure index values vary among manufacturers, and why is this important?
  • In radiography, high kVp is associated with which statement about grayscale?
  • Which parameter describes the system's ability to record a wide range of brightness levels?
  • What does exposure reproducibility mean in radiography, and how is it ensured?
  • Receptor exposure may be defined as which of the following?
  • The number of pixels making up the digital image is described by which term?
  • What is DICOM, and why is it essential in digital radiography?
  • Which parameter controls the number of gray shades per pixel?
  • Elongation occurs when the X-ray beam is angled along the long axis of a part.
  • What is the purpose of using standard presets in post-processing to avoid misrepresentation?
  • Which component of a digital detector is responsible for producing light after absorbing X-rays?
  • The primary controlling factor(s) of contrast is (are):
  • Compare the CR (PSP) workflow with the DR workflow.
  • Which single factor listed will increase spatial resolution?
  • Why is it important to track patient dose and maintain dose records for each exam?
  • The level of kVp that yields more uniform penetration through anatomy is which option?
  • What converts light into a charge?
  • How does pediatric imaging impact technique selection and dose?
  • The relationship between kVp and receptor exposure is best described as
  • To reduce patient dose, exposure technique in digital imaging should be adjusted by which change?
  • Explain detector lag and its potential impact on follow-up imaging.
  • Given an original technique of 30 mAs and 80 kVp, which would produce an image with double the receptor exposure?
  • A high SNR provides an image with:
  • Digital image receptors are more sensitive to which factor?
  • What allows more anatomic structures to be captured during an exposure?
  • A material that absorbs x-ray energy and emits part of that energy as visible light is called:
  • Contrast improvement factor is the measure of the grid's ability to enhance contrast.
  • As beam restriction tightens, receptor exposure what happens to receptor exposure?
  • Which statement about the role of kVp is accurate?
  • Which software function is used to bring uniform brightness across the image by smoothing?
  • What is a histogram in digital radiography, and why is histogram analysis performed after exposure?
  • The useful image acquisition area of an image receptor is which?
  • Which term describes the distance between centers of adjacent pixels?
  • Which change to exposure setup will increase magnification and potentially reduce spatial resolution?
  • What is a practical measure to prevent Moiré patterns in DR imaging?
  • What effect do radiographic grids have on contrast?
  • Why is technique documentation important in digital radiography performance and QA?
  • Quantum noise limits ability to see:
  • The element in the imaging chain that converts light into an electrical signal is the:
  • Smoothing software may result in:
  • In digital radiography, what is the effect of higher detector sampling frequency on spatial resolution?
  • The grid type with lead strips and aluminum interspacers angled to coincide with the divergence of the x-ray beam is called what?
  • How can the use of a technique chart reduce dose creep in a DR program?
  • What are the potential consequences of excessive edge enhancement on radiographic images?
  • The space from the center of a pixel to the center of the adjacent pixel is called:
  • What is the ALARA principle and how does dose tracking support it?
  • Why is dose optimization essential in digital radiography despite wide detector latitude?
  • Which are the primary controlling factors of receptor exposure?
  • In radiographic geometry, increasing the object-to-image distance (OID) will:
  • How does geometric unsharpness relate to focal spot size in radiography?
  • How does windowing influence image interpretation, and what pitfalls should be avoided?
  • What is the function of quantization in digital imaging?
  • What is the software function that evens the brightness displayed in the image called?
  • If the exposure field is not accurately recognized, the histogram will contain data:
  • The number of electrons that flow from the cathode to the anode in the tube is controlled by:
  • Gross overexposure of the IR results in:
  • Why is monitor calibration important in radiology imaging?
  • Reducing the object-to-image distance (OID) will have what effect on spatial resolution?
  • Distortion that occurs when the x-ray beam is angled along the long axis of a part is:
  • Which term describes a high-contrast image with limited gray tones?
  • Grid cutoff may be described as which phenomenon?
  • What is dose creep, and how can it be prevented?
  • In indirect conversion DR detectors, X-rays are first converted to what in the scintillator before becoming an electrical signal?
  • The number of pixels per millimeter in an image to the center of the adjacent pixel is called:
  • What is the effect of detector uniformity on image quality, and what can nonuniformity cause?
  • What is exposure latitude, and why do digital systems typically offer wider latitude than film-screen?
  • Which grid type provides the most effective scatter cleanup?
  • Optimal spatial resolution may be created using which of the following factors?
  • Bit depth is equal to:
  • Which of the following maintains image brightness over a wide range of exposures?
  • Which describes the relationship between mAs and receptor exposure?
  • What term describes the distance range within which a focused grid can be used?
  • An indicator of the dose level needed to acquire an optimal image is which metric?
  • What is the purpose of maintaining dose records for each exam?
  • The CR reader unit scans the IP with a which device?
  • What happens when automatic rescaling corrects for underexposure; what is a potential risk?
  • Which factor is most associated with reducing grid-related artifacts?
  • Technique charts: which statement is true?
  • Thicker part of anatomy should be placed under which aspect of the x-ray tube?
  • What is the fill factor in digital detectors and how does it affect image quality?
  • Explain the difference between window width and window level and their clinical use.
  • Lower spatial resolution may be caused by which factor?
  • Define quantum mottle and its relationship to exposure.